D1401-98
Standard Test Method for Water Separability of Petroleum Oils and Synthetic Fluids


1.1 This test method covers measurement of the ability of petroleum oils or synthetic fluids to separate from water.

Note 1-Although developed specifically for steam-turbine oils having viscosities of 28.8-90 cSt (mm /s) at 40°C, this test method can be used to test oils of other types having various viscosities and synthetic fluids. It is recommended, however, that the test temperature be raised to 82 + 1°C when testing products more viscous than 90 cSt (mm /s) at 40°C. For higher viscosity oils where there is insufficient mixing of oil and water, Test Method D-2711, is recommended. Other test temperatures such as 25°C can also be used. When testing synthetic fluids whose relative densities are greater than that of water, the procedure is unchanged, but it should be noted that the water will probably float on the emulsion or liquid.

                               