D88-94 (2005) 1.1 This test method
covers the empirical procedures for determining the Saybolt Universal or Saybolt
Furol viscosities of petroleum products at specified temperatures between 21 and
99°C (70 and 210°F). A special procedure for waxy products is indicated. Note-1Test Methods
D-445 and D-2170 are preferred
for the determination of kinematic viscosity. They require smaller samples and
less time, and provide greater accuracy. Kinematic viscosities may be converted
to Saybolt viscosities by use of the tables in Practice
D-2161. It is recommended that viscosity indexes be calculated from
kinematic rather than Saybolt viscosities.