Application Notes:
 

Pensky-Martens closed tester


is an apparatus used in determining the flash point of fuel oils and cutback asphalt, under conditions prescribed by test method ASTM-D-93. The test sample is slowly heated in a closed cup, at a specified constant rate, with continual stirring. A small flame is introduced into the cup at specified intervals through shuttered openings. The lowest temperature at which the vapors above the sample briefly ignite is the flash point.

Also see Tag closed tester.

 

Back to P  List                Index     

REAL Services          700 Portage Trail            Cuyahoga Falls, OH            44221.3057

voice: 330.630.3700        fax: 330.630.3733

© 1995-2005 REAL Services®  U.S.A. - Analytical Almanac All Rights Reserved