ISO-6619
Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration


1.1 This test method covers procedures for the determination of acidic constituents in petroleum products and lubricants soluble or nearly soluble in mixtures of toluene and propan-2-ol (Note 1). It is applicable for the determination of acids whose dissociation constants in water are larger than 10 -9 ; extremely weak acids whose dissociation constants are smaller than 10 -9 do not interfere. Salts react if their hydrolysis constants are larger than 10 -9 .

Note 1-In new and used oils, the constituents that may be considered to have acidic characteristics include organic and inorganic acids, esters, phenolic compounds, lactones, resins, salts of heavy metals, salts of ammonia and other weak bases, acid salts of polybasic acids, and addition agents such as inhibitors and detergents.

1.2 The test method may be used to indicate relative changes that occur in an oil during use under oxidizing conditions regardless of the color or other properties of the resulting oil. Although the titration is made under definite equilibrium conditions, the test method is not intended to measure an absolute acidic property that can be used to predict performance of an oil under service conditions. No general relationship between bearing corrosion and acid number is known.

Note 2-The acid number obtained by this standard may or may not be numerically the same as that obtained in accordance with Test Methods D-974 and D-3339.

Also see:    D-664

                               

REAL Services          700 Portage Trail            Cuyahoga Falls, OH            44221.3057

voice: 330.630.3700        fax: 330.630.3733