ISO-11500 Particle Count


Technique for detecting and categorizing particles in a used lube oil resulting from wear or contamination. Standard particle count is the ISO-11500 (International Standards Organization).  Only from the ISO-11500 can the ISO-11171 Solid Contamination Code be derived.  By the ISO test a laser passes through  a specified opening, as the fluid pass through, perpendicular to the laser source, particles and debris block out the laser source and by measuring the time of blockage determine the size of particles in the following size range:
 

 

> 4 µm
 

> 6 µm

 

> 14 µm

 

> 21 µm

 

> 38 µm

  > 70 µm


Other non-direct particle count methods include: Flow Rate Decay, Electro Conductivity, Optical Density Equivalent, Magnetic Mass Equitant and others.  In the test, algorithms are calculated to approximate the particle quantities in each given size range.

                               